{"product_id":"mfi-500-auto-volumetric-melt-flow-indexer","title":"MFI-500-AUTO Volumetric Melt Flow Indexer","description":"\u003ch2 data-streamdown=\"heading-2\" class=\"mt-6 mb-2 font-semibold text-2xl\"\u003eFully Automated Plastometer with Motorised Weight Loading\u003c\/h2\u003e\n\u003cp\u003eThe MFI-500-AUTO is an advanced computerised melt flow indexer featuring motorised automatic weight application. Designed for high-throughput laboratories, this instrument maximises reproducibility while minimising operator intervention—delivering consistent, reliable results test after test.\u003c\/p\u003e\n\u003ch2 data-streamdown=\"heading-2\" class=\"mt-6 mb-2 font-semibold text-2xl\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eMelt flow index measurement is essential for characterising thermoplastic materials, particularly when reliability, precision, and repeatability are critical. The MFI-500-AUTO elevates standard melt flow testing by automating the weight loading process, eliminating a key source of operator variability.\u003c\/p\u003e\n\u003cp\u003eProgram your test parameters and the instrument automatically applies the correct load. This motorised system reduces handling time, increases throughput, and ensures consistent weight placement across every test cycle—making the MFI-500-AUTO the ideal choice for demanding QC environments.\u003c\/p\u003e\n\u003ch2 data-streamdown=\"heading-2\" class=\"mt-6 mb-2 font-semibold text-2xl\"\u003eKey Features\u003c\/h2\u003e\n\u003ch3 data-streamdown=\"heading-3\" class=\"mt-6 mb-2 font-semibold text-xl\"\u003eMotorized Automatic Weight Loading\u003c\/h3\u003e\n\u003cp\u003eThe defining feature of the MFI-500-AUTO. The motorised system automatically applies test weights according to programmed parameters, reducing operator dependency and maximizing test-to-test consistency.\u003c\/p\u003e\n\u003ch3 data-streamdown=\"heading-3\" class=\"mt-6 mb-2 font-semibold text-xl\"\u003eDual-Method Testing\u003c\/h3\u003e\n\u003cp\u003eSupports both \u003cspan data-streamdown=\"strong\" class=\"font-semibold\"\u003eMethod A (gravimetric)\u003c\/span\u003e and \u003cspan data-streamdown=\"strong\" class=\"font-semibold\"\u003eMethod B (volumetric)\u003c\/span\u003e per ASTM D1238 and ISO 1133. Full compliance with international standards in one automated platform.\u003c\/p\u003e\n\u003ch3 data-streamdown=\"heading-3\" class=\"mt-6 mb-2 font-semibold text-xl\"\u003eComputerised Operation\u003c\/h3\u003e\n\u003cp\u003eIntegrated Mini PC with dedicated Melt Flow Index software manages test programming, automated weight application, timing, data acquisition, and results calculation.\u003c\/p\u003e\n\u003ch3 data-streamdown=\"heading-3\" class=\"mt-6 mb-2 font-semibold text-xl\"\u003ePrecision Temperature Control\u003c\/h3\u003e\n\u003cp\u003ePID-regulated heating maintains barrel temperature within \u003cspan data-streamdown=\"strong\" class=\"font-semibold\"\u003e±0.1°C\u003c\/span\u003e across a range up to \u003cspan data-streamdown=\"strong\" class=\"font-semibold\"\u003e325°C\u003c\/span\u003e, ensuring consistent test conditions for the full spectrum of thermoplastic materials.\u003c\/p\u003e\n\u003ch3 data-streamdown=\"heading-3\" class=\"mt-6 mb-2 font-semibold text-xl\"\u003eAutomatic Sample Cutting\u003c\/h3\u003e\n\u003cp\u003eProgrammable cutting cycles with adjustable time intervals and cut counts. Combined with automatic weight loading, this enables true semi-automated operation.\u003c\/p\u003e\n\u003ch3 data-streamdown=\"heading-3\" class=\"mt-6 mb-2 font-semibold text-xl\"\u003eOptimised Weight Set\u003c\/h3\u003e\n\u003cp\u003eSeven chrome-polished weights configured for automatic loading: \u003cspan data-streamdown=\"strong\" class=\"font-semibold\"\u003e0.15, 0.875, 0.96, 1.2, 1.64, 5.0, and 11.6 kg\u003c\/span\u003e. Combine all weights plus the 0.175 kg piston weight to achieve 21.6 kg for high-load testing.\u003c\/p\u003e\n\u003ch3 data-streamdown=\"heading-3\" class=\"mt-6 mb-2 font-semibold text-xl\"\u003eCorrosion-Ready Construction\u003c\/h3\u003e\n\u003cp\u003eEngineered to handle aggressive polymers like PVC without compromising barrel integrity or measurement accuracy.\u003c\/p\u003e\n\u003ch3 data-streamdown=\"heading-3\" class=\"mt-6 mb-2 font-semibold text-xl\"\u003eDigital Stopwatch\u003c\/h3\u003e\n\u003cp\u003eBuilt-in timer with \u003cspan data-streamdown=\"strong\" class=\"font-semibold\"\u003e9999-second range\u003c\/span\u003e supports precise timing for all test protocols.\u003c\/p\u003e\n\u003ch3 data-streamdown=\"heading-3\" class=\"mt-6 mb-2 font-semibold text-xl\"\u003eData Connectivity\u003c\/h3\u003e\n\u003cp\u003eRS-232 output with USB converter enables seamless data export for SPC integration, reporting, and archival.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eParameter                        Specification\u003c\/strong\u003e\u003cbr\u003eTest Methods                     ASTM D1238 \/ ISO 1133 Methods A \u0026amp; B\u003cbr\u003eTemperature Range           Up to 325°C\u003cbr\u003eTemperature Resolution    ±0.1°C\u003cbr\u003ePiston Stroke                     Up to 25 mm\u003cbr\u003eStroke Resolution              ±0.1 mm\u003cbr\u003eTimer Range                      Up to 9999 seconds\u003cbr\u003eWeight Loading                 Motorised automatic\u003cbr\u003eData Interface                    RS-232 with USB converter\u003cbr\u003eCertification                       CE marked\u003c\/p\u003e\n\u003ch2 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eApplications\u003c\/h2\u003e\n\u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003ePolymer Types\u003c\/h3\u003e\n\u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eCommodity resins:\u003c\/span\u003e PE, PP, PS, PVC\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eEngineering plastics:\u003c\/span\u003e PET, PMMA, nylon (PA), PB\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eSpecialty polymers:\u003c\/span\u003e PTFE and fluoropolymers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eIndustries\u003c\/h3\u003e\n\u003cp\u003ePackaging · Automotive · Aerospace · Medical devices · Construction · Textiles · Pipe and fittings · Furniture · Toys · Consumer products\u003c\/p\u003e\n\u003ch2 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eStandards Compliance\u003c\/h2\u003e\n\u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eASTM D1238\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eISO 1133\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eDIN 1133\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eEN 1133\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eUNE 1133\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eMFI-500-AUTO plastometer with integrated Mini PC\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eMotorised automatic weight loading system\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eMelt Flow Index testing software\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eSeven-piece chrome weight set (0.15–11.6 kg)\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eStandard piston and capillary die\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eComplete tool kit for operation and cleaning\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eUSB interface cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Gravimetric method calculations require weighing extruded samples to 0.001 g resolution. A precision analytical balance is recommended (not included).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eIdeal For\u003c\/h2\u003e\n\u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eHigh-throughput QC operations with repetitive testing schedules\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eFacilities seeking maximum reproducibility and reduced operator variability\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eLaboratories requiring semi-automated or unattended operation\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003eProduction environments where testing speed and consistency directly impact workflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eWhy Choose Automated Weight Loading?\u003c\/h2\u003e\n\u003cp\u003eManual weight placement introduces subtle variations—different positioning, timing delays, handling inconsistencies. Over hundreds of tests, these small differences accumulate into measurable variability.\u003c\/p\u003e\n\u003cp\u003eThe MFI-500-AUTO's motorised system applies weights identically every time, delivering the consistency that rigorous quality control demands. For laboratories running high test volumes or operating under strict reproducibility requirements, automation isn't a luxury—it's a practical necessity.\u003c\/p\u003e","brand":"Tech Lab Systems","offers":[{"title":"Default Title","offer_id":44998539575478,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-melt-flow-indexer-MFI500AUTO-tls.jpg?v=1774326876","url":"https:\/\/hyleccontrols.com.au\/products\/mfi-500-auto-volumetric-melt-flow-indexer","provider":"Hylec Controls","version":"1.0","type":"link"}