{"product_id":"hga-200-multi-channel-direct-mercury-analyzer","title":"HGA-200 multi-channel direct mercury analyzer","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eClassification:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mercury Analyzer Series\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe HGA-200 Multi-Channel Direct Mercury Analyzer is a high-efficiency analytical instrument designed for the rapid and accurate determination of mercury in a wide range of sample types. It is fully compliant with internationally recognised mercury detection standards (EPA 7473) and modern environmental monitoring requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe system enables direct mercury measurement without chemical digestion or complex sample pretreatment, allowing laboratories to significantly improve workflow efficiency while reducing operational complexity and cost.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe HGA-200 is widely used for mercury determination in:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eEnvironmental monitoring and protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFood safety testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDisease control and public health\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMedical and pharmaceutical analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAgricultural testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGeological and mining samples\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMetallurgy and coal industries\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePetrochemical and industrial materials\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCosmetics and consumer products\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSoil analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUrban water supply and wastewater\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAcademic research and teaching\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eDirect Mercury Analysis Without Digestion\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eNo chemical digestion or pretreatment required\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSimply weigh the sample and perform direct injection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReduces analysis time and simplifies laboratory workflow\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eHigh-Throughput Multi-Channel Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eDual-channel system enables simultaneous analysis of two samples\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnalysis completed in as little as 2.5–5 minutes per sample\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEquipped with a 60-position autosampler for continuous unattended operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIncreases testing efficiency by up to 100%\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eLow Operating Cost\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eNo chemical reagents required during operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSignificantly reduces consumable costs and laboratory waste\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eHigh Accuracy and Stability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated flow path design ensures stable sample transport\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-efficiency composite catalyst improves reaction completeness\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNano gold-coated amalgamation system enhances mercury capture\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExcellent repeatability and analytical precision\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eNo Memory Effect or Mercury Loss\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eDirect injection system eliminates mercury loss\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFull temperature-controlled pathway minimises carryover and memory effects\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eEnvironmental Protection Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eGreen analytical process with no hazardous chemical usage\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated exhaust gas purification system with activated carbon adsorption\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePrevents secondary mercury pollution during analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eAdvanced Optical and Detection System\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eHighly selective UV detector tuned to mercury spectral line (253.7 nm)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNon-reflective dual-beam correction system reduces signal drift\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNo optical mirrors, eliminating contamination-related measurement errors\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eIntelligent Automation System\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic sample weighing data import via electronic balance interface\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFully automated sample injection and analysis process\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEmbedded multi-threaded software with real-time monitoring interface\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupports unattended operation and intelligent workflow management\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eHigh-Efficiency Catalysis and Interference Removal\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAdvanced catalytic technology effectively eliminates matrix interference\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eImproves sensitivity, repeatability, and measurement stability\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWorkflow Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\u003cspan\u003eWeigh sample\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePlace sample into sample boat\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic sample loading and analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eObtain results in 2–5 minutes\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eTypical sample throughput:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ~2.5 minutes per sample\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eSummary\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe HGA-200 Multi-Channel Direct Mercury Analyzer provides a fast, reliable, and cost-effective solution for mercury detection across a wide range of industries. With direct analysis technology, multi-channel efficiency, and full automation, it is ideally suited for high-throughput laboratories requiring accurate mercury measurement without complex sample preparation.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sinotest","offers":[{"title":"Default Title","offer_id":45158480871606,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-HGA-200-multi-channel-direct-mercury-analyzer-sino.jpg?v=1780367718","url":"https:\/\/hyleccontrols.com.au\/products\/hga-200-multi-channel-direct-mercury-analyzer","provider":"Hylec Controls","version":"1.0","type":"link"}