{"product_id":"ggx-910-zeeman-flame-atomic-absorption-spectrophotometer","title":"GGX-910 zeeman flame atomic absorption spectrophotometer","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eClassification:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Flame Series\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe GGX-910 Zeeman Flame Atomic Absorption Spectrophotometer combines advanced Zeeman background correction technology with a high-performance flame atomisation system to deliver accurate and reliable elemental analysis. Developed from decades of expertise in atomic absorption spectroscopy, the GGX-910 offers exceptional analytical stability, intelligent automation, and comprehensive safety protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFeaturing a user-friendly software platform, robust optical design, and advanced flame control technology, the instrument is ideal for routine and high-precision analysis in environmental, food, pharmaceutical, industrial, and research laboratories.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eAdvanced Zeeman Background Correction\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eHigh-performance Zeeman background correction with full-spectrum background subtraction.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eImproves analytical accuracy by effectively compensating for complex matrix interferences.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eEnergy-Efficient Magnetic Field Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eTransverse Zeeman system with a constant magnetic field.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReduces power consumption while maintaining excellent correction performance and instrument stability.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eQuasi Double-Beam Optical System\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eNo preheating required for routine operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides fast startup and improved analytical efficiency.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAutomatic Eight-Lamp Turret\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic rotating lamp holder supporting up to eight element lamps.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSimultaneous preheating of all installed lamps reduces analysis preparation time.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePatented slip-ring design eliminates cable twisting and improves reliability.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eHigh-Performance Optical System\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eWavelength range: 190–900 nm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eAutomatic spectral bandwidth selection:\u003c\/span\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003e0.2 nm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e0.4 nm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1.0 nm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2.0 nm\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdvanced Czerny-Turner (C-T) optical design with a 270 mm focal length.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1800 lines\/mm diffraction grating provides excellent optical resolution and high energy throughput.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic wavelength peak search and optimisation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eIntelligent Instrument Automation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic peak setting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic bandwidth selection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic lamp positioning\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in self-diagnostic and fault detection systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eComprehensive instrument status monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003ePowerful Analytical Software\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAvailable in both English and Chinese.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdvanced data traceability and audit functions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSupports:\u003c\/span\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eStandard calibration curve method\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandard addition method\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCurve recalibration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSlope reset functions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEditable correction curves\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBlank correction and customised calibration management\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eFlame Atomisation System\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eFully Automated Gas Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic ignition and gas circuit control.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContinuously adjustable gas flow with automatic optimisation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eDurable Burner Assembly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eTitanium alloy burner head offers excellent resistance to heat and corrosion.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDesigned for long service life and stable analytical performance.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eHigh-Efficiency Nebulisation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003ePremix burner system with all-plastic corrosion-resistant nebuliser chamber.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-sensitivity glass nebuliser provides excellent sample atomisation and analytical sensitivity.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAdvanced Safety Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe GGX-910 incorporates a comprehensive safety interlock system to ensure safe operation:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic water seal monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIgnition lockout when water levels are insufficient\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir and acetylene pressure monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIgnition prevention under low-pressure conditions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic flame monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic gas shut-off if flame extinguishment is detected\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAnti-flashback protection system\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWaste liquid level monitoring to prevent overflow\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eIntelligent Safety Diagnostics\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMultiple self-diagnostic functions continuously monitor operating conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic fault detection and protection mechanisms minimise risk and downtime.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe GGX-910 is suitable for a broad range of analytical applications, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eFood safety and hygiene testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnvironmental monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWater quality analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGeological and mining laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMetallurgical testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAgricultural analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical industry quality control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePharmaceutical testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommodity inspection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUniversities and research institutions\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eDetectable Elements\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe GGX-910 is capable of determining more than 70 metallic elements, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGold (Au), Silver (Ag), Copper (Cu), Lead (Pb), Zinc (Zn), Manganese (Mn), Potassium (K), Sodium (Na), Calcium (Ca), Magnesium (Mg), Iron (Fe), Cadmium (Cd), and many others.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSuitable sample types include food products, surface water, groundwater, drinking water, environmental samples, industrial materials, agricultural products, and geological specimens.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe advanced Zeeman background correction system makes the GGX-910 particularly well suited for complex sample matrices where high analytical accuracy and interference correction are critical.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sinotest","offers":[{"title":"Default Title","offer_id":45158193037494,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-ggx-910-zeeman-flame-atomic-absorption-spectrophotometer-sino.jpg?v=1780365734","url":"https:\/\/hyleccontrols.com.au\/products\/ggx-910-zeeman-flame-atomic-absorption-spectrophotometer","provider":"Hylec Controls","version":"1.0","type":"link"}