{"product_id":"ggx-830-atomic-absorption-spectrophotometer","title":"GGX-830 atomic absorption spectrophotometer","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eClassification:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Flame and Graphite Furnace Integrated Series\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe GGX-830 Atomic Absorption Spectrophotometer is a high-performance analytical instrument developed from decades of expertise in atomic absorption spectroscopy. As part of Haiguang's proven product range, the GGX-830 combines flame and graphite furnace atomisation technologies in a single integrated platform, delivering excellent sensitivity, stability, and analytical accuracy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDesigned for routine and advanced elemental analysis, the instrument offers a high degree of automation, comprehensive safety protection, and powerful data processing capabilities. Its intuitive software interface and flexible operation make it an ideal solution for environmental, food, pharmaceutical, industrial, and research laboratories.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eAdvanced Atomic Absorption System\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eIntegrated flame and graphite furnace atomic absorption spectrometer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-performance deuterium lamp background correction for improved analytical accuracy.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSimultaneous illumination or preheating of up to eight lamps for enhanced productivity.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShort optical path design delivers higher energy throughput and superior sensitivity.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOne-touch switching between flame and graphite furnace operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eHigh Automation and Productivity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003ePatented 52-position graphite furnace autosampler.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic calibration curve generation and optimisation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlexible matrix modifier addition.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInjection accuracy of ≤ ±0.5%.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic instrument optimisation and parameter adjustment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eEnhanced Stability and Reliability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eOptimised EMC design incorporating advanced EMI (electromagnetic interference) and EMS (electromagnetic susceptibility) protection.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnsures stable operation and reliable analytical performance in demanding laboratory environments.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eComprehensive Safety Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eIntelligent monitoring and protection systems safeguard instrument operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContinuous monitoring of critical operating parameters with automatic fault detection and protection.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003ePowerful Data Processing Software\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAutomated instrument control and optimisation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMultiple calibration and concentration calculation methods.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlexible data management, reporting, and export functions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eOptical System\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWavelength Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 190–900 nm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWavelength Repeatability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026lt; 0.1 nm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWavelength Accuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026lt; ±0.2 nm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSpectral Bandwidth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0.2, 0.4, 1.0, 2.0 nm (automatic switching)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBaseline Drift:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026lt; 0.003 A \/ 30 min\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMonochromator:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Optimised aberration-corrected C-T monochromator with automatic peak search and scanning\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eGrating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Czerny-Turner optical design, 270 mm focal length, 1800 lines\/mm diffraction grating\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDetector:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e High-sensitivity photomultiplier tube with wide spectral response\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eResolution:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Complete separation of manganese double lines (279.5 nm and 279.8 nm) at 0.2 nm bandwidth\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLamp Turret:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 8-lamp automatic rotating and aligning system\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBackground Correction Capability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ≥ 60 times\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eFlame Atomisation System\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eHigh-Performance Burner\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eTitanium alloy burner head with excellent resistance to heat and corrosion.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThree-dimensional adjustment for optimum flame conditions.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eEfficient Nebulisation System\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eExplosion-proof atomisation chamber.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCorrosion-resistant design with high-efficiency glass nebuliser.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEasy maintenance and cleaning.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAutomatic Gas Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eFully computer-controlled gas flow regulation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic burner position and angle optimisation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic ignition and burner identification.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAdvanced Safety Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eComprehensive safety interlock system.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eContinuous monitoring of:\u003c\/span\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eGas pressure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlame status\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWater seal condition\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBurner head operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNebuliser pressure\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic shutdown during abnormal operation or power failure.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAcetylene leak detection and emergency shutdown protection.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eLiquid Level Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic waste liquid level detection prevents overflow and enhances laboratory safety.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eGraphite Furnace Atomisation System\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003ePrecision Temperature Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eTemperature range from ambient to 3000°C.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic temperature calibration and self-correction.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature control accuracy ≤ 1%.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaximum heating rate ≥ 2000°C\/s.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eFlexible Heating Programs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eUp to 10 programmable heating stages.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eThree heating modes:\u003c\/span\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eStep\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRamp\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHold\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLongitudinal heating technology ensures uniform temperature distribution.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAdvanced Safety Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eGraphite furnace temperature monitoring.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCooling water pressure monitoring.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInert gas pressure monitoring.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGraphite tube breakage and installation detection.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAutomatic Protection Functions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eArgon under-pressure warning.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCooling water flow alarms.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOver-temperature and over-current protection.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic system shutdown when required.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eData Processing and Reporting\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eFlexible Quantification Methods\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eStandard calibration curve method (1–3 curves)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic curve fitting\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandard addition method\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRepetitive measurement capability (1–99 replicates)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eStatistical Analysis\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cspan\u003eAutomatic calculation of:\u003c\/span\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eMean values\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandard deviation (SD)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRelative standard deviation (RSD)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eReporting and Data Export\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eAnalytical parameter reports\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResult and graphical output printing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eComprehensive report generation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData storage and export to Excel for further analysis and reporting\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe GGX-830 is widely used for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eFood safety and hygiene testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnvironmental monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWater quality analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGeological and mining laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMetallurgical testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAgricultural analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical industry quality control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePharmaceutical testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommodity inspection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUniversities and research institutions\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eDetectable Elements\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe GGX-830 can accurately determine more than 70 metallic elements, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eGold (Au), Silver (Ag), Copper (Cu), Lead (Pb), Zinc (Zn), Manganese (Mn), Potassium (K), Sodium (Na), Calcium (Ca), Magnesium (Mg), Iron (Fe), Cadmium (Cd), and many others.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSuitable sample types include food products, surface water, groundwater, drinking water, environmental samples, industrial materials, and geological specimens.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sinotest","offers":[{"title":"Default Title","offer_id":45158160662710,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-ggx-830-atomic-absorption-spectrophotometer-sino.jpg?v=1780365563","url":"https:\/\/hyleccontrols.com.au\/products\/ggx-830-atomic-absorption-spectrophotometer","provider":"Hylec Controls","version":"1.0","type":"link"}