{"product_id":"afs-9710-afs-9750-afs-9770-atomic-fluorescence-spectrophotometer","title":"AFS-9710 \/ AFS-9750 \/ AFS-9770 Atomic Fluorescence Spectrophotometer","description":"\u003cp data-start=\"76\" data-end=\"125\"\u003e\u003cstrong data-start=\"76\" data-end=\"103\"\u003eProduct classification:\u003c\/strong\u003e Syringe Pump Series\u003c\/p\u003e\n\u003chr data-start=\"127\" data-end=\"130\"\u003e\n\u003ch3 data-section-id=\"f0xuy6\" data-start=\"132\" data-end=\"154\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"155\" data-end=\"579\"\u003eThe AFS-97 Series Atomic Fluorescence Spectrophotometers, are high-performance instruments designed for ultra-trace element analysis. They are widely used for the detection of arsenic (As), mercury (Hg), selenium (Se), antimony (Sb), and other trace elements across environmental monitoring, food safety, quality inspection, geology, mining, and scientific research applications.\u003c\/p\u003e\n\u003chr data-start=\"581\" data-end=\"584\"\u003e\n\u003ch3 data-section-id=\"1sboupi\" data-start=\"586\" data-end=\"604\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"606\" data-end=\"3616\"\u003e\n\u003cli data-section-id=\"dxfer9\" data-start=\"606\" data-end=\"763\"\u003e\n\u003cstrong data-start=\"608\" data-end=\"651\"\u003eHigh-sensitivity multi-element analysis\u003c\/strong\u003e\u003cbr data-start=\"651\" data-end=\"654\"\u003eEnables ultra-trace detection of up to twelve elements, including arsenic, mercury, selenium, and antimony.\u003c\/li\u003e\n\u003cli data-section-id=\"1aam911\" data-start=\"765\" data-end=\"971\"\u003e\n\u003cstrong data-start=\"767\" data-end=\"803\"\u003eFlexible multi-channel detection\u003c\/strong\u003e\n\u003cul data-start=\"808\" data-end=\"971\"\u003e\n\u003cli data-section-id=\"17w8i6c\" data-start=\"808\" data-end=\"868\"\u003eAFS-9710 \/ AFS-9750: simultaneous analysis of 2 elements\u003c\/li\u003e\n\u003cli data-section-id=\"7wtxsp\" data-start=\"871\" data-end=\"920\"\u003eAFS-9770: simultaneous analysis of 4 elements\u003c\/li\u003e\n\u003cli data-section-id=\"t4k56a\" data-start=\"923\" data-end=\"971\"\u003eSignificantly reduced analysis time per sample\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16iy28u\" data-start=\"973\" data-end=\"1196\"\u003e\n\u003cstrong data-start=\"975\" data-end=\"1017\"\u003eHigh-throughput sample handling system\u003c\/strong\u003e\u003cbr data-start=\"1017\" data-end=\"1020\"\u003eUltra-quiet, high-speed polar coordinate autosampler supports multiple tray configurations:\n\u003cul data-start=\"1118\" data-end=\"1196\"\u003e\n\u003cli data-section-id=\"1nur3hm\" data-start=\"1118\" data-end=\"1142\"\u003e69 positions (25 mL)\u003c\/li\u003e\n\u003cli data-section-id=\"1fm58k0\" data-start=\"1145\" data-end=\"1170\"\u003e134 positions (15 mL)\u003c\/li\u003e\n\u003cli data-section-id=\"1j6slo9\" data-start=\"1173\" data-end=\"1196\"\u003e183 positions (10 mL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qxydw8\" data-start=\"1198\" data-end=\"1393\"\u003e\n\u003cstrong data-start=\"1200\" data-end=\"1237\"\u003eAdvanced fluid control technology\u003c\/strong\u003e\u003cbr data-start=\"1237\" data-end=\"1240\"\u003eAFS-9750 features a 10-roller, 6-channel high-stability peristaltic pump system, ensuring consistent sample injection and minimising pulsation effects.\u003c\/li\u003e\n\u003cli data-section-id=\"1lrbsod\" data-start=\"1395\" data-end=\"1680\"\u003e\n\u003cstrong data-start=\"1397\" data-end=\"1447\"\u003eInnovative valve design for higher reliability\u003c\/strong\u003e\u003cbr data-start=\"1447\" data-end=\"1450\"\u003ePinch valve technology replaces traditional check valves and multi-channel valves, preventing reagent contact with valve components, eliminating corrosion and memory effects, and delivering a service life of over 500,000 cycles.\u003c\/li\u003e\n\u003cli data-section-id=\"10leji\" data-start=\"1682\" data-end=\"1849\"\u003e\n\u003cstrong data-start=\"1684\" data-end=\"1710\"\u003eHybrid pump technology\u003c\/strong\u003e\u003cbr data-start=\"1710\" data-end=\"1713\"\u003eCombines syringe pump precision with peristaltic pump speed, enabling accurate injection, fast processing, and online system cleaning.\u003c\/li\u003e\n\u003cli data-section-id=\"zane5n\" data-start=\"1851\" data-end=\"1994\"\u003e\n\u003cstrong data-start=\"1853\" data-end=\"1892\"\u003eAutomated operation and calibration\u003c\/strong\u003e\u003cbr data-start=\"1892\" data-end=\"1895\"\u003eSupports single-point calibration, automatic dilution, and fully automated measurement workflows.\u003c\/li\u003e\n\u003cli data-section-id=\"1k23i91\" data-start=\"1996\" data-end=\"2139\"\u003e\n\u003cstrong data-start=\"1998\" data-end=\"2032\"\u003eEnhanced measurement stability\u003c\/strong\u003e\u003cbr data-start=\"2032\" data-end=\"2035\"\u003eSample and current isolation technology reduces diffusion interference, improving analytical accuracy.\u003c\/li\u003e\n\u003cli data-section-id=\"xvidjk\" data-start=\"2141\" data-end=\"2321\"\u003e\n\u003cstrong data-start=\"2143\" data-end=\"2175\"\u003eOptimised atomisation system\u003c\/strong\u003e\u003cbr data-start=\"2175\" data-end=\"2178\"\u003eShielded quartz furnace low-temperature atomiser reduces fluorescence quenching and gas-phase interference, improving atomisation efficiency.\u003c\/li\u003e\n\u003cli data-section-id=\"sanj4m\" data-start=\"2323\" data-end=\"2490\"\u003e\n\u003cstrong data-start=\"2325\" data-end=\"2366\"\u003eAdvanced gas–liquid separation system\u003c\/strong\u003e\u003cbr data-start=\"2366\" data-end=\"2369\"\u003eAirtight two-stage separation design eliminates the need for liquid replenishment and waste discharge during operation.\u003c\/li\u003e\n\u003cli data-section-id=\"i6976q\" data-start=\"2492\" data-end=\"2625\"\u003e\n\u003cstrong data-start=\"2494\" data-end=\"2525\"\u003eSmart instrument management\u003c\/strong\u003e\u003cbr data-start=\"2525\" data-end=\"2528\"\u003eAutomatic element recognition and intelligent monitoring of coded hollow cathode lamp lifespan.\u003c\/li\u003e\n\u003cli data-section-id=\"10ypaz5\" data-start=\"2627\" data-end=\"2764\"\u003e\n\u003cstrong data-start=\"2629\" data-end=\"2660\"\u003eEfficient gas system design\u003c\/strong\u003e\u003cbr data-start=\"2660\" data-end=\"2663\"\u003eArray-type gas circuit with advanced throttling technology significantly reduces argon consumption.\u003c\/li\u003e\n\u003cli data-section-id=\"1qorllu\" data-start=\"2766\" data-end=\"2910\"\u003e\n\u003cstrong data-start=\"2768\" data-end=\"2803\"\u003eBuilt-in safety and diagnostics\u003c\/strong\u003e\u003cbr data-start=\"2803\" data-end=\"2806\"\u003eIncludes startup self-check, real-time diagnostics, and automatic fault alarms for reliable operation.\u003c\/li\u003e\n\u003cli data-section-id=\"pqa9vt\" data-start=\"2912\" data-end=\"3032\"\u003e\n\u003cstrong data-start=\"2914\" data-end=\"2945\"\u003eFlame monitoring capability\u003c\/strong\u003e\u003cbr data-start=\"2945\" data-end=\"2948\"\u003eArgon-hydrogen flame observation window enables real-time flame status monitoring.\u003c\/li\u003e\n\u003cli data-section-id=\"1b79mqz\" data-start=\"3034\" data-end=\"3192\"\u003e\n\u003cstrong data-start=\"3036\" data-end=\"3081\"\u003eHighly integrated electronic architecture\u003c\/strong\u003e\u003cbr data-start=\"3081\" data-end=\"3084\"\u003eModular circuit design with separation of high- and low-voltage systems for improved stability and safety.\u003c\/li\u003e\n\u003cli data-section-id=\"7ky258\" data-start=\"3194\" data-end=\"3345\"\u003e\n\u003cstrong data-start=\"3196\" data-end=\"3231\"\u003eUser-friendly software platform\u003c\/strong\u003e\u003cbr data-start=\"3231\" data-end=\"3234\"\u003eCompatible with Windows XP \/ 7 \/ 8 \/ 10, featuring intuitive operation and built-in expert online assistance.\u003c\/li\u003e\n\u003cli data-section-id=\"dzky0j\" data-start=\"3347\" data-end=\"3471\"\u003e\n\u003cstrong data-start=\"3349\" data-end=\"3381\"\u003eData integration and sharing\u003c\/strong\u003e\u003cbr data-start=\"3381\" data-end=\"3384\"\u003eSupports quick export of results to Excel for streamlined reporting and data sharing.\u003c\/li\u003e\n\u003cli data-section-id=\"1ren1it\" data-start=\"3473\" data-end=\"3616\"\u003e\n\u003cstrong data-start=\"3475\" data-end=\"3513\"\u003eExpandable analytical capabilities\u003c\/strong\u003e\u003cbr data-start=\"3513\" data-end=\"3516\"\u003eReserved speciation analysis interfaces to support advanced user requirements and future upgrades.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3618\" data-end=\"3621\"\u003e\n\u003ch3 data-section-id=\"97uleg\" data-start=\"3623\" data-end=\"3646\"\u003eApplication Areas\u003c\/h3\u003e\n\u003cp data-start=\"3647\" data-end=\"3939\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe AFS-97 Series is widely applied in:\u003cbr data-start=\"3686\" data-end=\"3689\"\u003eEnvironmental protection, food safety, disease control, medical and health laboratories, agriculture, geology and mining, metallurgy, cosmetics, soil analysis, urban water supply and drainage, as well as teaching and scientific research institutions.\u003c\/p\u003e","brand":"Sinotest","offers":[{"title":"Default Title","offer_id":45152654721206,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-atomic-fluoresence-spectrophotometer-afs-97-series-sino.jpg?v=1780298967","url":"https:\/\/hyleccontrols.com.au\/products\/afs-9710-afs-9750-afs-9770-atomic-fluorescence-spectrophotometer","provider":"Hylec Controls","version":"1.0","type":"link"}