{"product_id":"afs-9560-afs-9561-afs-9562-atomic-fluorescence-spectrophotometer","title":"AFS-9560 \/ AFS-9561 \/ AFS-9562 Atomic Fluorescence Spectrophotometer","description":"\u003cp data-start=\"76\" data-end=\"125\"\u003e\u003cstrong data-start=\"76\" data-end=\"103\"\u003eProduct classification:\u003c\/strong\u003e Syringe Pump Series\u003c\/p\u003e\n\u003chr data-start=\"127\" data-end=\"130\"\u003e\n\u003ch3 data-start=\"132\" data-end=\"154\" data-section-id=\"f0xuy6\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"155\" data-end=\"563\"\u003eThe AFS-95 Series Atomic Fluorescence Spectrophotometer, independently developed by Haiguang Company, is designed for high-sensitivity trace and ultra-trace elemental analysis. It is widely used for detecting arsenic (As), mercury (Hg), selenium (Se), antimony (Sb), and other trace elements in environmental monitoring, food safety, quality inspection, geology, mining, and scientific research applications.\u003c\/p\u003e\n\u003chr data-start=\"565\" data-end=\"568\"\u003e\n\u003ch3 data-start=\"570\" data-end=\"588\" data-section-id=\"1sboupi\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"590\" data-end=\"3573\"\u003e\n\u003cli data-start=\"590\" data-end=\"754\" data-section-id=\"131eete\"\u003e\n\u003cstrong data-start=\"592\" data-end=\"635\"\u003eMulti-element trace analysis capability\u003c\/strong\u003e\u003cbr data-start=\"635\" data-end=\"638\"\u003eSuitable for the determination of up to twelve trace elements, including arsenic, mercury, selenium, and antimony.\u003c\/li\u003e\n\u003cli data-start=\"756\" data-end=\"907\" data-section-id=\"wygwdp\"\u003e\n\u003cstrong data-start=\"758\" data-end=\"792\"\u003eHigh-throughput optical system\u003c\/strong\u003e\u003cbr data-start=\"792\" data-end=\"795\"\u003eFeatures four lamp positions, dual-channel detection, and fully automated measurement for improved efficiency.\u003c\/li\u003e\n\u003cli data-start=\"909\" data-end=\"1101\" data-section-id=\"1j2l691\"\u003e\n\u003cstrong data-start=\"911\" data-end=\"946\"\u003eFlexible sample handling system\u003c\/strong\u003e\u003cbr data-start=\"946\" data-end=\"949\"\u003ePolar coordinate autosampler supports multiple tray configurations:\n\u003cul data-start=\"1023\" data-end=\"1101\"\u003e\n\u003cli data-start=\"1023\" data-end=\"1047\" data-section-id=\"1nur3hm\"\u003e69 positions (25 mL)\u003c\/li\u003e\n\u003cli data-start=\"1050\" data-end=\"1075\" data-section-id=\"1fm58k0\"\u003e134 positions (15 mL)\u003c\/li\u003e\n\u003cli data-start=\"1078\" data-end=\"1101\" data-section-id=\"1j6slo9\"\u003e183 positions (10 mL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1103\" data-end=\"1262\" data-section-id=\"1yox1px\"\u003e\n\u003cstrong data-start=\"1105\" data-end=\"1139\"\u003eAdvanced fluid delivery system\u003c\/strong\u003e\u003cbr data-start=\"1139\" data-end=\"1142\"\u003eEquipped with an original imported dual syringe pump made from specialised materials for high precision and stability.\u003c\/li\u003e\n\u003cli data-start=\"1264\" data-end=\"1432\" data-section-id=\"c0q62t\"\u003e\n\u003cstrong data-start=\"1266\" data-end=\"1292\"\u003eHybrid pump technology\u003c\/strong\u003e\u003cbr data-start=\"1292\" data-end=\"1295\"\u003eCombines syringe pump accuracy with peristaltic pump speed, enabling fast injection, precise dosing, and online cleaning functionality.\u003c\/li\u003e\n\u003cli data-start=\"1434\" data-end=\"1596\" data-section-id=\"1y55d9d\"\u003e\n\u003cstrong data-start=\"1436\" data-end=\"1467\"\u003eImproved valve architecture\u003c\/strong\u003e\u003cbr data-start=\"1467\" data-end=\"1470\"\u003eDiaphragm valve system replaces traditional multi-channel valves, reducing dead volume and improving safety and reliability.\u003c\/li\u003e\n\u003cli data-start=\"1598\" data-end=\"1781\" data-section-id=\"1ow7vut\"\u003e\n\u003cstrong data-start=\"1600\" data-end=\"1636\"\u003eLong-life pinch valve technology\u003c\/strong\u003e\u003cbr data-start=\"1636\" data-end=\"1639\"\u003eEliminates reagent contact with valve bodies, preventing corrosion and memory effects, and delivering a service life of over 500,000 cycles.\u003c\/li\u003e\n\u003cli data-start=\"1783\" data-end=\"1911\" data-section-id=\"1frpfp3\"\u003e\n\u003cstrong data-start=\"1785\" data-end=\"1819\"\u003eAutomated analytical workflows\u003c\/strong\u003e\u003cbr data-start=\"1819\" data-end=\"1822\"\u003eSupports single-point calibration, automatic dilution, and fully automated measurement.\u003c\/li\u003e\n\u003cli data-start=\"1913\" data-end=\"2037\" data-section-id=\"uik03h\"\u003e\n\u003cstrong data-start=\"1915\" data-end=\"1951\"\u003eSemi-automatic operation support\u003c\/strong\u003e\u003cbr data-start=\"1951\" data-end=\"1954\"\u003eHigh-performance coding system enables flexible semi-automatic measurement modes.\u003c\/li\u003e\n\u003cli data-start=\"2039\" data-end=\"2175\" data-section-id=\"1m28pmy\"\u003e\n\u003cstrong data-start=\"2041\" data-end=\"2075\"\u003eEnhanced measurement stability\u003c\/strong\u003e\u003cbr data-start=\"2075\" data-end=\"2078\"\u003eSample and current isolation technology minimises diffusion interference for improved accuracy.\u003c\/li\u003e\n\u003cli data-start=\"2177\" data-end=\"2368\" data-section-id=\"1md3aw3\"\u003e\n\u003cstrong data-start=\"2179\" data-end=\"2217\"\u003eHigh-efficiency atomisation system\u003c\/strong\u003e\u003cbr data-start=\"2217\" data-end=\"2220\"\u003eShielded quartz furnace low-temperature atomiser reduces fluorescence quenching and gas-phase interference while improving atomisation efficiency.\u003c\/li\u003e\n\u003cli data-start=\"2370\" data-end=\"2511\" data-section-id=\"1cjbvug\"\u003e\n\u003cstrong data-start=\"2372\" data-end=\"2411\"\u003eClosed gas–liquid separation system\u003c\/strong\u003e\u003cbr data-start=\"2411\" data-end=\"2414\"\u003eNew airtight two-stage design eliminates the need for liquid replenishment and waste discharge.\u003c\/li\u003e\n\u003cli data-start=\"2513\" data-end=\"2647\" data-section-id=\"1u665e5\"\u003e\n\u003cstrong data-start=\"2515\" data-end=\"2549\"\u003eIntelligent instrument control\u003c\/strong\u003e\u003cbr data-start=\"2549\" data-end=\"2552\"\u003eAutomatic element recognition and real-time monitoring of coded hollow cathode lamp lifespan.\u003c\/li\u003e\n\u003cli data-start=\"2649\" data-end=\"2781\" data-section-id=\"1eja18j\"\u003e\n\u003cstrong data-start=\"2651\" data-end=\"2686\"\u003eOptimised gas management system\u003c\/strong\u003e\u003cbr data-start=\"2686\" data-end=\"2689\"\u003eArray-type gas circuit with advanced flow control significantly reduces argon consumption.\u003c\/li\u003e\n\u003cli data-start=\"2783\" data-end=\"2911\" data-section-id=\"1o30cte\"\u003e\n\u003cstrong data-start=\"2785\" data-end=\"2828\"\u003eBuilt-in diagnostics and safety systems\u003c\/strong\u003e\u003cbr data-start=\"2828\" data-end=\"2831\"\u003eIncludes startup self-check, automatic diagnostics, and fault alarm functions.\u003c\/li\u003e\n\u003cli data-start=\"2913\" data-end=\"3039\" data-section-id=\"1h9ogfl\"\u003e\n\u003cstrong data-start=\"2915\" data-end=\"2945\"\u003eReal-time flame monitoring\u003c\/strong\u003e\u003cbr data-start=\"2945\" data-end=\"2948\"\u003eArgon-hydrogen flame observation window allows continuous monitoring of flame conditions.\u003c\/li\u003e\n\u003cli data-start=\"3041\" data-end=\"3193\" data-section-id=\"vc87za\"\u003e\n\u003cstrong data-start=\"3043\" data-end=\"3078\"\u003eModular electronic architecture\u003c\/strong\u003e\u003cbr data-start=\"3078\" data-end=\"3081\"\u003eHighly integrated circuit board design with separation of high and low voltage systems for improved stability.\u003c\/li\u003e\n\u003cli data-start=\"3195\" data-end=\"3335\" data-section-id=\"1wtcpc0\"\u003e\n\u003cstrong data-start=\"3197\" data-end=\"3232\"\u003eUser-friendly software platform\u003c\/strong\u003e\u003cbr data-start=\"3232\" data-end=\"3235\"\u003eCompatible with Windows XP \/ 7 \/ 8 \/ 10, featuring expert online guidance and intuitive operation.\u003c\/li\u003e\n\u003cli data-start=\"3337\" data-end=\"3452\" data-section-id=\"h86zj7\"\u003e\n\u003cstrong data-start=\"3339\" data-end=\"3370\"\u003eData export and integration\u003c\/strong\u003e\u003cbr data-start=\"3370\" data-end=\"3373\"\u003eSupports fast export to Excel for easy analysis, reporting, and data sharing.\u003c\/li\u003e\n\u003cli data-start=\"3454\" data-end=\"3573\" data-section-id=\"flytkk\"\u003e\n\u003cstrong data-start=\"3456\" data-end=\"3484\"\u003eExpandable functionality\u003c\/strong\u003e\u003cbr data-start=\"3484\" data-end=\"3487\"\u003eReserved speciation analysis interfaces to support advanced analytical requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3575\" data-end=\"3578\"\u003e\n\u003ch3 data-start=\"3580\" data-end=\"3603\" data-section-id=\"97uleg\"\u003eApplication Areas\u003c\/h3\u003e\n\u003cp data-start=\"3604\" data-end=\"3892\"\u003eThe AFS-95 Series is widely used in environmental protection, food safety, disease control, medical and health laboratories, agriculture, geology and mining, metallurgy, cosmetics, soil analysis, urban water supply and drainage, as well as teaching and scientific research institutions.\u003c\/p\u003e","brand":"Sinotest","offers":[{"title":"Default Title","offer_id":45152661242038,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-atomic-fluoresence-spectrophotometer-afs-95-series-sino.jpg?v=1780299520","url":"https:\/\/hyleccontrols.com.au\/products\/afs-9560-afs-9561-afs-9562-atomic-fluorescence-spectrophotometer","provider":"Hylec Controls","version":"1.0","type":"link"}