{"title":"Vector BTC","description":"","products":[{"product_id":"vicatron-6x-12x-automatic-vicat","title":"Vicatron 6x \u0026amp; 12x Automatic Vicat Testing Devices","description":"\u003cp data-start=\"279\" data-end=\"340\"\u003e\u003cstrong data-start=\"279\" data-end=\"290\"\u003eModels:\u003c\/strong\u003e VTR-1022X6 (6-Station) | VTR-1022X12 (12-Station)\u003c\/p\u003e\n\u003cp data-start=\"342\" data-end=\"510\"\u003eExperience exceptional precision and productivity in cement consistency and setting time testing with the \u003cstrong data-start=\"448\" data-end=\"499\"\u003eVicatron Series Automatic Vicat Testing Devices\u003c\/strong\u003e by Vector.\u003c\/p\u003e\n\u003cp data-start=\"512\" data-end=\"850\"\u003eDesigned for professional cement laboratories, the Vicatron 6x and 12x deliver automated, high-throughput testing that ensures accuracy, repeatability, and full compliance with \u003cstrong data-start=\"689\" data-end=\"701\"\u003eEN 196-3\u003c\/strong\u003e and \u003cstrong data-start=\"706\" data-end=\"719\"\u003eASTM C191\u003c\/strong\u003e standards. Choose between \u003cstrong data-start=\"746\" data-end=\"759\"\u003e6-station\u003c\/strong\u003e or \u003cstrong data-start=\"763\" data-end=\"777\"\u003e12-station\u003c\/strong\u003e configurations to match your testing capacity and workflow requirements.\u003c\/p\u003e\n\u003chr data-start=\"852\" data-end=\"855\"\u003e\n\u003ch3 data-start=\"857\" data-end=\"879\"\u003e\u003cstrong data-start=\"861\" data-end=\"879\"\u003eKey Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"881\" data-end=\"1012\"\u003e\u003cstrong data-start=\"881\" data-end=\"907\"\u003e✔ Standards Compliance\u003c\/strong\u003e\u003cbr data-start=\"907\" data-end=\"910\"\u003eMeets \u003cstrong data-start=\"916\" data-end=\"928\"\u003eEN 196-3\u003c\/strong\u003e and \u003cstrong data-start=\"933\" data-end=\"946\"\u003eASTM C191\u003c\/strong\u003e, ensuring reliable and internationally recognised test results.\u003c\/p\u003e\n\u003cp data-start=\"1014\" data-end=\"1182\"\u003e\u003cstrong data-start=\"1014\" data-end=\"1044\"\u003e✔ Multi-Station Efficiency\u003c\/strong\u003e\u003cbr data-start=\"1044\" data-end=\"1047\"\u003eSelect between 6 or 12 test stations for simultaneous multi-sample analysis — ideal for busy laboratories needing maximum throughput.\u003c\/p\u003e\n\u003cp data-start=\"1184\" data-end=\"1338\"\u003e\u003cstrong data-start=\"1184\" data-end=\"1211\"\u003e✔ Precision Measurement\u003c\/strong\u003e\u003cbr data-start=\"1211\" data-end=\"1214\"\u003eDelivers 0.01 mm penetration depth accuracy with adjustable penetration intervals for total control of testing parameters.\u003c\/p\u003e\n\u003cp data-start=\"1340\" data-end=\"1515\"\u003e\u003cstrong data-start=\"1340\" data-end=\"1372\"\u003e✔ Comprehensive Data Capture\u003c\/strong\u003e\u003cbr data-start=\"1372\" data-end=\"1375\"\u003eAutomatically records \u003cstrong data-start=\"1397\" data-end=\"1408\"\u003einitial\u003c\/strong\u003e, \u003cstrong data-start=\"1410\" data-end=\"1419\"\u003efinal\u003c\/strong\u003e, and \u003cstrong data-start=\"1425\" data-end=\"1440\"\u003efalse final\u003c\/strong\u003e setting times, providing a complete understanding of cement performance.\u003c\/p\u003e\n\u003cp data-start=\"1517\" data-end=\"1754\"\u003e\u003cstrong data-start=\"1517\" data-end=\"1551\"\u003e✔ Intelligent Software Control\u003c\/strong\u003e\u003cbr data-start=\"1551\" data-end=\"1554\"\u003eVector’s advanced control software enables real-time monitoring, automatic data logging, and detailed PDF report generation — complete with operator name, company logo, and archived historical data.\u003c\/p\u003e\n\u003cp data-start=\"1756\" data-end=\"1962\"\u003e\u003cstrong data-start=\"1756\" data-end=\"1795\"\u003e✔ Built-In Safety \u0026amp; Low Maintenance\u003c\/strong\u003e\u003cbr data-start=\"1795\" data-end=\"1798\"\u003eIncludes motion-limit safety sensors, a contactless needle drop system, and automatic needle cleaning to prevent residue build-up and maintain long-term accuracy.\u003c\/p\u003e\n\u003cp data-start=\"1964\" data-end=\"2108\"\u003e\u003cstrong data-start=\"1964\" data-end=\"1994\"\u003e✔ Simple, Secure Operation\u003c\/strong\u003e\u003cbr data-start=\"1994\" data-end=\"1997\"\u003ePassword protection, USB data transfer, and intuitive controls simplify operation and enhance data integrity.\u003c\/p\u003e\n\u003cp data-start=\"2110\" data-end=\"2281\"\u003e\u003cstrong data-start=\"2110\" data-end=\"2134\"\u003e✔ Dependable Support\u003c\/strong\u003e\u003cbr data-start=\"2134\" data-end=\"2137\"\u003eDelivered with a comprehensive warranty, guaranteed spare parts supply, and ongoing software and technical support for complete peace of mind.\u003c\/p\u003e\n\u003chr data-start=\"2283\" data-end=\"2286\"\u003e\n\u003ch3 data-start=\"2288\" data-end=\"2304\"\u003e\u003cstrong data-start=\"2292\" data-end=\"2304\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2306\" data-end=\"2715\"\u003eThe \u003cstrong data-start=\"2310\" data-end=\"2325\"\u003eVicatron 6x\u003c\/strong\u003e and \u003cstrong data-start=\"2330\" data-end=\"2346\"\u003eVicatron 12x\u003c\/strong\u003e deliver \u003cstrong data-start=\"2355\" data-end=\"2374\"\u003efully automated\u003c\/strong\u003e, \u003cstrong data-start=\"2376\" data-end=\"2407\"\u003eindependent station control\u003c\/strong\u003e for testing cement setting characteristics under identical or varied conditions.\u003cbr data-start=\"2488\" data-end=\"2491\"\u003eEach impact and penetration event is captured in real time with \u003cstrong data-start=\"2555\" data-end=\"2576\"\u003e0.1 mm resolution\u003c\/strong\u003e, while the integrated, temperature-controlled water tank ensures stable, traceable testing conditions for both dry and underwater methods.\u003c\/p\u003e\n\u003cp data-start=\"2717\" data-end=\"3011\"\u003eUser-friendly software allows direct adjustment of needle height, calibration, and testing intervals, offering complete flexibility for both \u003cstrong data-start=\"2858\" data-end=\"2870\"\u003eresearch\u003c\/strong\u003e and \u003cstrong data-start=\"2875\" data-end=\"2902\"\u003eroutine quality control\u003c\/strong\u003e. Automated cleaning, motion-limit sensors, and precision mechanics minimise maintenance and maximise uptime.\u003c\/p\u003e\n\u003cp data-start=\"3013\" data-end=\"3153\"\u003eCustomisable PDF reports summarise every stage of testing, while unlimited data storage and USB export simplify long-term result management.\u003c\/p\u003e\n\u003chr data-start=\"3155\" data-end=\"3158\"\u003e\n\u003ch3 data-start=\"3160\" data-end=\"3180\"\u003e\u003cstrong data-start=\"3164\" data-end=\"3180\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3182\" data-end=\"3520\"\u003e\n\u003cli data-start=\"3182\" data-end=\"3273\"\u003e\n\u003cp data-start=\"3184\" data-end=\"3273\"\u003e\u003cstrong data-start=\"3184\" data-end=\"3222\"\u003eConstruction \u0026amp; Building Materials:\u003c\/strong\u003e Routine cement quality control and certification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3274\" data-end=\"3364\"\u003e\n\u003cp data-start=\"3276\" data-end=\"3364\"\u003e\u003cstrong data-start=\"3276\" data-end=\"3307\"\u003eCivil Engineering Research:\u003c\/strong\u003e Setting behaviour studies for infrastructure materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3365\" data-end=\"3435\"\u003e\n\u003cp data-start=\"3367\" data-end=\"3435\"\u003e\u003cstrong data-start=\"3367\" data-end=\"3396\"\u003eEducational Institutions:\u003c\/strong\u003e Academic and training laboratory use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3436\" data-end=\"3520\"\u003e\n\u003cp data-start=\"3438\" data-end=\"3520\"\u003e\u003cstrong data-start=\"3438\" data-end=\"3469\"\u003eIndustrial Quality Control:\u003c\/strong\u003e High-volume cement and binder production testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3522\" data-end=\"3525\"\u003e\n\u003ch3 data-start=\"3527\" data-end=\"3559\"\u003e\u003cstrong data-start=\"3531\" data-end=\"3559\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3561\" data-end=\"4814\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3561\" data-end=\"3619\"\u003e\n\u003ctr data-start=\"3561\" data-end=\"3619\"\u003e\n\u003cth data-start=\"3561\" data-end=\"3581\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3563\" data-end=\"3580\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"3581\" data-end=\"3599\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3583\" data-end=\"3598\"\u003eVicatron 6x\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"3599\" data-end=\"3619\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3601\" data-end=\"3617\"\u003eVicatron 12x\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3680\" data-end=\"4814\"\u003e\n\u003ctr data-start=\"3680\" data-end=\"3725\"\u003e\n\u003ctd data-start=\"3680\" data-end=\"3697\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3682\" data-end=\"3696\"\u003eModel Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3697\" data-end=\"3710\" data-col-size=\"sm\"\u003eVTR-1022X6\u003c\/td\u003e\n\u003ctd data-start=\"3710\" data-end=\"3725\" data-col-size=\"sm\"\u003eVTR-1022X12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3726\" data-end=\"3761\"\u003e\n\u003ctd data-start=\"3726\" data-end=\"3751\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3728\" data-end=\"3750\"\u003eNumber of Stations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3751\" data-end=\"3755\" data-col-size=\"sm\"\u003e6\u003c\/td\u003e\n\u003ctd data-start=\"3755\" data-end=\"3761\" data-col-size=\"sm\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3762\" data-end=\"3834\"\u003e\n\u003ctd data-start=\"3762\" data-end=\"3789\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3764\" data-end=\"3788\"\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3789\" data-end=\"3811\" data-col-size=\"sm\"\u003eEN 196-3, ASTM C191\u003c\/td\u003e\n\u003ctd data-start=\"3811\" data-end=\"3834\" data-col-size=\"sm\"\u003eEN 196-3, ASTM C191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3835\" data-end=\"3889\"\u003e\n\u003ctd data-start=\"3835\" data-end=\"3868\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3837\" data-end=\"3867\"\u003ePenetration Depth Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3868\" data-end=\"3878\" data-col-size=\"sm\"\u003e0.01 mm\u003c\/td\u003e\n\u003ctd data-start=\"3878\" data-end=\"3889\" data-col-size=\"sm\"\u003e0.01 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3890\" data-end=\"3927\"\u003e\n\u003ctd data-start=\"3890\" data-end=\"3910\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3892\" data-end=\"3909\"\u003eNeedle Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3910\" data-end=\"3918\" data-col-size=\"sm\"\u003e300 g\u003c\/td\u003e\n\u003ctd data-start=\"3918\" data-end=\"3927\" data-col-size=\"sm\"\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3928\" data-end=\"4006\"\u003e\n\u003ctd data-start=\"3928\" data-end=\"3953\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3930\" data-end=\"3952\"\u003eNeedle Drop Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3953\" data-end=\"3979\" data-col-size=\"sm\"\u003eAdjustable via software\u003c\/td\u003e\n\u003ctd data-start=\"3979\" data-end=\"4006\" data-col-size=\"sm\"\u003eAdjustable via software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4007\" data-end=\"4084\"\u003e\n\u003ctd data-start=\"4007\" data-end=\"4035\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4009\" data-end=\"4034\"\u003ePenetration Step Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4035\" data-end=\"4059\" data-col-size=\"sm\"\u003e1 – 999 min (dynamic)\u003c\/td\u003e\n\u003ctd data-start=\"4059\" data-end=\"4084\" data-col-size=\"sm\"\u003e1 – 999 min (dynamic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4085\" data-end=\"4152\"\u003e\n\u003ctd data-start=\"4085\" data-end=\"4111\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4087\" data-end=\"4110\"\u003eTesting Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4111\" data-end=\"4131\" data-col-size=\"sm\"\u003eDry or underwater\u003c\/td\u003e\n\u003ctd data-start=\"4131\" data-end=\"4152\" data-col-size=\"sm\"\u003eDry or underwater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4153\" data-end=\"4257\"\u003e\n\u003ctd data-start=\"4153\" data-end=\"4170\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4155\" data-end=\"4169\"\u003eWater Tank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4170\" data-end=\"4213\" data-col-size=\"sm\"\u003eIntegrated with circulation and drainage\u003c\/td\u003e\n\u003ctd data-start=\"4213\" data-end=\"4257\" data-col-size=\"sm\"\u003eIntegrated with circulation and drainage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4258\" data-end=\"4346\"\u003e\n\u003ctd data-start=\"4258\" data-end=\"4277\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4260\" data-end=\"4276\"\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4277\" data-end=\"4311\" data-col-size=\"sm\"\u003eTemperature \u0026amp; penetration depth\u003c\/td\u003e\n\u003ctd data-start=\"4311\" data-end=\"4346\" data-col-size=\"sm\"\u003eTemperature \u0026amp; penetration depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4347\" data-end=\"4448\"\u003e\n\u003ctd data-start=\"4347\" data-end=\"4371\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4349\" data-end=\"4370\"\u003eSoftware Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4371\" data-end=\"4409\" data-col-size=\"sm\"\u003eReal-time monitoring, PDF reporting\u003c\/td\u003e\n\u003ctd data-start=\"4409\" data-end=\"4448\" data-col-size=\"sm\"\u003eReal-time monitoring, PDF reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4449\" data-end=\"4481\"\u003e\n\u003ctd data-start=\"4449\" data-end=\"4468\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4451\" data-end=\"4467\"\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4468\" data-end=\"4474\" data-col-size=\"sm\"\u003eUSB\u003c\/td\u003e\n\u003ctd data-start=\"4474\" data-end=\"4481\" data-col-size=\"sm\"\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4482\" data-end=\"4587\"\u003e\n\u003ctd data-start=\"4482\" data-end=\"4504\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4484\" data-end=\"4503\"\u003eSafety Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4504\" data-end=\"4545\" data-col-size=\"sm\"\u003eMotion-limit sensors, contactless drop\u003c\/td\u003e\n\u003ctd data-start=\"4545\" data-end=\"4587\" data-col-size=\"sm\"\u003eMotion-limit sensors, contactless drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4588\" data-end=\"4677\"\u003e\n\u003ctd data-start=\"4588\" data-end=\"4606\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4590\" data-end=\"4605\"\u003eMaintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4606\" data-end=\"4641\" data-col-size=\"sm\"\u003eAutomatic needle cleaning system\u003c\/td\u003e\n\u003ctd data-start=\"4641\" data-end=\"4677\" data-col-size=\"sm\"\u003eAutomatic needle cleaning system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4678\" data-end=\"4726\"\u003e\n\u003ctd data-start=\"4678\" data-end=\"4697\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4680\" data-end=\"4696\"\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4697\" data-end=\"4711\" data-col-size=\"sm\"\u003e220 V 50 Hz\u003c\/td\u003e\n\u003ctd data-start=\"4711\" data-end=\"4726\" data-col-size=\"sm\"\u003e220 V 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4727\" data-end=\"4814\"\u003e\n\u003ctd data-start=\"4727\" data-end=\"4741\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4729\" data-end=\"4740\"\u003eSupport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4741\" data-end=\"4777\" data-col-size=\"sm\"\u003eFull software \u0026amp; technical support\u003c\/td\u003e\n\u003ctd data-start=\"4777\" data-end=\"4814\" data-col-size=\"sm\"\u003eFull software \u0026amp; technical support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4816\" data-end=\"4819\"\u003e\n\u003ch3 data-start=\"4821\" data-end=\"4836\"\u003e\u003cstrong data-start=\"4825\" data-end=\"4836\"\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4838\" data-end=\"5230\"\u003eThe \u003cstrong data-start=\"4842\" data-end=\"4857\"\u003eVicatron 6x\u003c\/strong\u003e and \u003cstrong data-start=\"4862\" data-end=\"4910\"\u003eVicatron 12x Automatic Vicat Testing Devices\u003c\/strong\u003e redefine the standard for precision and productivity in cement testing.\u003cbr data-start=\"4982\" data-end=\"4985\"\u003eWith automated operation, intelligent software control, and robust engineering, they deliver consistent, traceable, and high-quality results — helping laboratories meet the highest standards of \u003cstrong data-start=\"5179\" data-end=\"5191\"\u003eaccuracy\u003c\/strong\u003e, \u003cstrong data-start=\"5193\" data-end=\"5207\"\u003eefficiency\u003c\/strong\u003e, and \u003cstrong data-start=\"5213\" data-end=\"5227\"\u003ecompliance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"5232\" data-end=\"5316\"\u003e\u003cstrong data-start=\"5232\" data-end=\"5316\"\u003eExperience the future of cement setting time analysis — with Vicatron by Vector.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Vector BTC","offers":[{"title":"Default Title","offer_id":44378033193142,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-vicatron-12-automatic-vicat-vectorbtc2.jpg?v=1762224645"}],"url":"https:\/\/hyleccontrols.com.au\/collections\/vector-btc.oembed","provider":"Hylec Controls","version":"1.0","type":"link"}