{"title":"Rebar","description":"","products":[{"product_id":"concrete-cover-meter-rebar-detector","title":"Concrete Cover Meter Rebar Detector","description":"\u003cp\u003eThe Concrete Cover Meter Rebar Detector is designed for precise measurement of concrete cover thickness, rebar location, and diameter estimation in reinforced concrete structures. Ideal for use in construction sites, operational buildings, and testing environments, this advanced device helps ensure structural integrity and compliance with quality standards.\u003c\/p\u003e\n\u003ch3\u003eKey Functions \u0026amp; Advantages:\u003c\/h3\u003e\n\u003ch4\u003eConcrete Cover Thickness Measurement\u003c\/h4\u003e\n\u003cp\u003eThe primary function of the Concrete Cover Meter is to accurately measure the thickness of the concrete cover in reinforced structures. With an accuracy of up to 170 mm, the device adapts to various rebar diameters, providing reliable measurements crucial for compliance and safety.\u003c\/p\u003e\n\u003ch4\u003eScanning \u0026amp; Detection Mode\u003c\/h4\u003e\n\u003cp\u003eIn scanning mode, the detector identifies the presence and position of rebars, offering optional audio signals to simplify rebar detection without continuous screen monitoring.\u003c\/p\u003e\n\u003ch4\u003eRebar Diameter Estimation\u003c\/h4\u003e\n\u003cp\u003eThe device includes a diameter estimation mode that approximates rebar diameter by measuring distances with and without a reference plate. While not precise, this feature offers a useful estimate in non-critical applications.\u003c\/p\u003e\n\u003ch4\u003eErgonomic \u0026amp; Durable Design\u003c\/h4\u003e\n\u003cp\u003eBuilt to endure tough conditions, the Concrete Cover Meter features a shock-resistant, dust- and moisture-proof housing, making it ideal for challenging industrial environments.\u003c\/p\u003e\n\u003ch3\u003eEnhanced Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial-grade, durable housing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eresistant to dust, moisture, and impacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-contrast display\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith adjustable brightness and contrast, metric or imperial units, and multilingual options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal probe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith built-in memory for saved calibration tables and backup\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended battery life\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand improved accuracy, offering stable measurements without added cost\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eThickness Measurement Range\u003c\/td\u003e\n\u003ctd\u003e5–170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRebar Diameter Range\u003c\/td\u003e\n\u003ctd\u003e6–50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e(0.03 h + 0.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance Standards\u003c\/td\u003e\n\u003ctd\u003eBS 1881 Part 204, DIN 1045, SN 505262, SS 78-B4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (Electronic Unit)\u003c\/td\u003e\n\u003ctd\u003e122 × 76 × 36.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (Probe)\u003c\/td\u003e\n\u003ctd\u003e200 × 50 × 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e2 AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Operation\u003c\/td\u003e\n\u003ctd\u003e8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eImportant Notes:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiameter Estimation Mode\u003c\/strong\u003e: Intended for approximate measurements only, as accuracy may vary depending on the sample (see Media video 1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration\u003c\/strong\u003e: Only requires a simple zero-point calibration for use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRebar Proximity Limitations\u003c\/strong\u003e: Accurate readings may be challenging if rebars are positioned within 100 mm of each other, a common limitation for cover meters of this type.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Concrete Cover Meter Rebar Detector combines functionality and durability, providing professionals with essential tools to assess and ensure concrete integrity across various construction and industrial settings.\u003c\/p\u003e","brand":"NOVOTEST","offers":[{"title":"Default Title","offer_id":40483140010166,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/products\/hylec-controls-novotest-Concrete-Cover-Meter-Rebar-Detector.png?v=1630548602"},{"product_id":"rebar-coupler-cyclic-testing-machine","title":"Rebar coupler cyclic testing machine","description":"\u003ch3\u003eRebar coupler cyclic testing machine\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eWANCE sevvo-hydraulic universal testing machine HUT-DP type is designed with side action grip which enable tension and compression cyclic test, complying with AC133 test requirements.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAC133  ACCEPTANCE CRITERIA FOR MECHANICAL CONNECTOR SYSTEMS FOR STEEL REINFORCING BARS\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePurpose: The purpose of this acceptance criteria is to establish requirements for mechanical connector systems for steel reinforcing bars to be recognised in an\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eICC Evaluation Service, LLC (ICC-ES), evaluation report under the 2012 and 2009 International Building Code® (IBC) and the 2012 and 2009 International Residential\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCode® (IRC). The bases of recognition are IBC Section 104.11 and IRC Section R104.11.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe reason for development of this criteria is to establish guidelines for the evaluation of mechanical connector systems for steel reinforcing bars and to provide additional information to clarify the requirements of the IBC, and IRC, and documents referenced by those codes. \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Wance Group","offers":[{"title":"Default Title","offer_id":41731883532470,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/products\/hylec-controls-servo-hydraulic-utm-Rebar-coupler-cyclic-testing-machine-wance.jpg?v=1661439703"},{"product_id":"rebarscope-advanced-system-for-rebar-location-and-bar-size-determination","title":"REBARSCOPE® advanced system for rebar location and bar size determination","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eRebarscope®\u003c\/span\u003e\u003cspan\u003e is the digital version of a classic rebar locator, rebar finder which enables the user to not only locate reinforcement bars but also determine rebar depth and the rebar size. The \u003c\/span\u003e\u003cspan\u003eRebarscope®\u003c\/span\u003e\u003cspan\u003e rebar locator is also capable of locating non ferrous metals as well such as copper, aluminium, some stainless steels, wire, and more!\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003e\u003ca name=\"fb\"\u003eFeatures \u0026amp; Benefits\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEddy current sensor design for greater accuracy with built in temperature compensation, no need to zero the sensor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSingle sensor for all depth ranges.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSeparate sensor and main instrumentation unit to scan difficult to access area's.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLocates rebar, post tension cable, conduit,and copper pipe.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRugged and splash resistant case. \u003c\/span\u003e\u003cspan\u003eDaylight visible display.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOptional Scan Cart logs distance data as well as the location of rebar.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLocates up to 8\" (200 mm) deep. \u003c\/span\u003e\u003cspan\u003eDetermines bar size up to 4.5\" (115 mm) deep.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConforms to ACI 318, BS 1881 Part 204, DIN 1045, CP 110, EC 2, SIA\u0026lt; 162, DGZfP B2.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003e\u003ca name=\"apps\"\u003eApplications\u003c\/a\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eStructural Engineers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eRebar Mapping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eRebar Network Analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eUtility Mapping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eMain Unit\u003c\/h3\u003e\n\u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eWeight:\u003c\/span\u003e 5.4 lbs (2.5 kg)\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eDimensions:\u003c\/span\u003e 10.63\" L × 9.68\" W × 4.88\" H (27 × 24.5 × 12.4 cm)\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eDisplay:\u003c\/span\u003e 320 × 240 pixel LCD, 3.5\" × 4.65\" (8.9 × 11.8 cm)\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003ePower:\u003c\/span\u003e 18V rechargeable, 4-6 hours continuous runtime\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eMemory:\u003c\/span\u003e 80,000 data point capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eSensor Probe\u003c\/h3\u003e\n\u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eWeight:\u003c\/span\u003e 1 lb (0.45 kg)\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eDimensions:\u003c\/span\u003e 5\" L × 2.4\" W × 1.6\" H (12.7 × 6 × 4.1 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"mt-6 mb-2 font-semibold text-xl\" data-streamdown=\"heading-3\"\u003eOptional Scan Cart\u003c\/h3\u003e\n\u003cul class=\"list-inside list-disc whitespace-normal [li_\u0026amp;]:pl-6\" data-streamdown=\"unordered-list\"\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eWeight:\u003c\/span\u003e 1 lb (0.45 kg)\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eDimensions:\u003c\/span\u003e 8.25\" L × 5.6\" W × 2.25\" H (20.1 × 14.2 × 5.7 cm)\u003c\/li\u003e\n\u003cli class=\"py-1 [\u0026amp;\u0026gt;p]:inline\" data-streamdown=\"list-item\"\u003e\n\u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eMaximum Scan Length:\u003c\/span\u003e 48 ft (14.6 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eStandards Compliance\u003c\/h2\u003e\n\u003cp\u003eMeets requirements for: \u003cspan class=\"font-semibold\" data-streamdown=\"strong\"\u003eACI 318, BS 1881 Part 204, DIN 1045, CP 110, EC 2, SIA 162, DGZfP B2\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"mt-6 mb-2 font-semibold text-2xl\" data-streamdown=\"heading-2\"\u003eWhy Choose Rebarscope®?\u003c\/h2\u003e\n\u003cp\u003eThe Rebarscope® combines decades of proven rebar location technology with modern digital precision. Its advanced microprocessor technology delivers consistent, repeatable results while the ruggedised design ensures reliable performance in demanding field conditions. Whether you're conducting structural assessments, mapping reinforcement networks, or locating utilities, the Rebarscope® provides the accuracy and reliability professionals demand.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eR-C-400 BASIC UNIT \u003c\/span\u003e\u003cspan\u003eincludes the following: Main Unit, Probe, 8 ft Cable, Sizing Template, Charger, and Headphones\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eR-C-450 BASIC UNIT WITH SOFTWARE includes the following: Main Unit, Probe, 8 ft Cable, Sizing Template, Charger, Headphones, USB Cable, and Basic Software.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eR-C-475 SCAN CART UPGRADE includes the following: Scan Cart, 2 Extension Rods, 12 ft Cable, Scanning Software. Turns your Basic Unit into a complete system (R-C-410).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eR-C-410 COMPLETE SYSTEM includes the following: Main Unit, Probe, 8 ft \u0026amp; 12 ft Cable, Scan Cart, Headphones, Charger, Complete Software (Basic and Scanning Software), USB Cable, Sizing Template, 2 Extension Rods\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"NDT James Instruments","offers":[{"title":"Default Title","offer_id":42153740173494,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/products\/hylec-controls-rebarscope-rebar-location-bar-size-determinator.png?v=1678839540"},{"product_id":"gecor-8™-advanced-rebar-corrosion-rate-determination-system","title":"Gecor 8™ Advanced Rebar Corrosion Rate Determination System","description":"\u003cp\u003e\u003cstrong\u003eGecor 8™ - Advanced Corrosion Analysis System for Reinforced Concrete\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe Gecor 8™ is the leading solution for accurately analyzing corrosion in steel-reinforced concrete structures. Designed for in-depth assessment of existing infrastructure, it helps engineers estimate service life, analyse structural corrosion rates, and project repair costs with exceptional precision. Using the latest in microprocessor and flash technology, the Gecor 8™ delivers reliable, data-driven insights to maintain structural integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate Corrosion Rate Analysis\u003c\/strong\u003e: Incorporates an advanced modulation confinement technique, providing the most accurate field measurement of corrosion rate, as confirmed by the US Strategic Highway Research Program.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid Mapping Capabilities\u003c\/strong\u003e: Quickly maps corrosion rates across large structures, allowing for efficient classification and targeted analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubmersion-Ready Design\u003c\/strong\u003e: Features new sensors optimised for wet or submerged structures, making it versatile for various environmental conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCathodic Protection Analysis\u003c\/strong\u003e: Measures cathodic protection efficiency in active systems to assess and optimise corrosion control methods.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser-Friendly Software\u003c\/strong\u003e: PC software offers a graphical interface for easy data analysis, report generation, and contour mapping, aiding in seamless data collection and processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCorrosion rate analysis for concrete reinforcement\u003c\/li\u003e\n\u003cli\u003eStructural service life estimation\u003c\/li\u003e\n\u003cli\u003eCost forecasting for repairs and rehabilitation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Technology\u003c\/strong\u003e\u003cbr\u003eThe Gecor 8™ leverages advanced polarization resistance techniques to deliver real-time, accurate corrosion measurements. Its rapid mapping and data analytics software produce multi-color contour maps, displaying risk areas for immediate action. The system's unique modulation confinement adapts to concrete conditions, providing consistent, quasi-steady-state readings within 30-100 seconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 9 lbs (4 kg) for main unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 12 x 8 x 6.5 in. (300 x 200 x 360 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e: Rechargeable nickel hydride batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay\u003c\/strong\u003e: LCD 320 x 240 1\/4 VGA for clear data visualisation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensors\u003c\/strong\u003e: Optional configurations for varied analysis environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"NDT James Instruments","offers":[{"title":"Default Title","offer_id":42209401176246,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/products\/hylec-controls-gecor-8-steel-corrosion-rate-determination-bar-ndtjames.jpg?v=1682051784"},{"product_id":"cor-map-ii-®-advanced-half-cell-potential-system-for-locating-areas-of-rebar-corrosion","title":"COR-MAP II ® advanced half cell potential system for locating areas of rebar corrosion","description":"\u003cdiv class=\"flex-1 overflow-hidden\"\u003e\n\u003cdiv class=\"react-scroll-to-bottom--css-zmbfi-79elbk h-full dark:bg-gray-800\"\u003e\n\u003cdiv class=\"react-scroll-to-bottom--css-zmbfi-1n7m0yu\"\u003e\n\u003cdiv class=\"flex flex-col items-center text-sm dark:bg-gray-800\"\u003e\n\u003cdiv class=\"group w-full text-gray-800 dark:text-gray-100 border-b border-black\/10 dark:border-gray-900\/50 bg-gray-50 dark:bg-[#444654]\"\u003e\n\u003cdiv class=\"text-base gap-4 md:gap-6 md:max-w-2xl lg:max-w-xl xl:max-w-3xl p-4 md:py-6 flex lg:px-0 m-auto\"\u003e\n\u003cdiv class=\"relative flex w-[calc(100%-50px)] flex-col gap-1 md:gap-3 lg:w-[calc(100%-115px)]\"\u003e\n\u003cdiv class=\"flex flex-grow flex-col gap-3\"\u003e\n\u003cdiv class=\"min-h-[20px] flex flex-col items-start gap-4 whitespace-pre-wrap\"\u003e\n\u003cdiv class=\"markdown prose w-full break-words dark:prose-invert light\"\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced System for corrosion potential data acquisition and analysis, allowing the user to quickly identify areas of probable corrosion in the field.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIntroducing the Corrosion Mapping System, a cutting-edge technology designed for the rapid identification of corroded steel reinforcement in concrete. With its advanced half-cell potential measurement technique conforming to ASTM C--876 Standard Method, the Corrosion Mapping System detects areas of corroded steel reinforcement without the need for costly and time-consuming demolition of concrete.\u003c\/p\u003e\n\u003cp\u003eThis innovative system features ruggedised electronics, enabling quick and efficient data analysis in both field and office environments. Its electrode design is versatile, suitable for use in horizontal, vertical, and inverted positions, and its temperature and humidity sensors allow for environmental conditions to be included in data analysis.\u003c\/p\u003e\n\u003cp\u003eThe Corrosion Mapping System's advanced data acquisition and analysis system enables the user to identify areas of probable corrosion, estimate repair costs, and determine the service life of structures. It works by measuring and mapping the voltage potential across the surface of the concrete, detecting areas of rust with high corrosion that exhibit significantly lower voltages than areas without corrosion.\u003c\/p\u003e\n\u003cp\u003eThis system is an efficient, cost-effective, and reliable solution for engineers and contractors involved in the maintenance, rehabilitation, and repair of concrete structures. With the Corrosion Mapping System, locating corroding steel reinforcement and estimating repair costs has never been easier.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NDT James Instruments","offers":[{"title":"Default Title","offer_id":42209413693622,"sku":"","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-cor-map-11-ndt-james-equipment2.jpg?v=1692597185"},{"product_id":"covermaster-rebar-locator-and-concrete-covermeter","title":"Elcometer 331 - Advanced Rebar Locator and Concrete Covermeter","description":"\u003cp\u003eThe CoverMaster (Elcometer 331) is a portable and precise instrument designed for locating rebar and measuring concrete cover in reinforced structures. Utilising pulse-induction technology, it ensures accuracy and convenience for a wide range of applications. A current pulse is applied to coils in the search head, creating a magnetic field that induces eddy currents in rebar. By measuring the amplitude of these currents, the device determines the rebar's orientation, depth and size.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRebar Detection:\u003c\/strong\u003e The search head scans the concrete surface to locate the exact position and orientation of rebar. When the bar is directly under the search head, the signal peaks, allowing the device to measure depth and estimate the diameter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighly Stable Measurements:\u003c\/strong\u003e The CoverMaster's technique remains unaffected by moisture, magnetic aggregates, temperature fluctuations, or electrical interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterchangeable Search Heads:\u003c\/strong\u003e A variety of easily interchangeable search heads are available, allowing flexibility to meet different project needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHalf-Cell Potential Measurement:\u003c\/strong\u003e The CoverMaster can be used with half-cell electrode probes to measure corrosion potential according to ASTM C876, making it a valuable tool for condition surveys of reinforced concrete structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLocate reinforcing bars and metal cable ducts in concrete.\u003c\/li\u003e\n\u003cli\u003eMeasure the concrete cover depth over reinforcement.\u003c\/li\u003e\n\u003cli\u003eEstimate rebar diameter.\u003c\/li\u003e\n\u003cli\u003eIdentify metal objects embedded in concrete.\u003c\/li\u003e\n\u003cli\u003eConduct condition surveys for corrosion activity using half-cell potential methods (ASTM C876).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 7.4V battery pack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Life:\u003c\/strong\u003e 32 hours of continuous use (20 hours with backlight).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecharging Time:\u003c\/strong\u003e 4 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 230 x 130 x 125 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.6 kg (without accessories).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHalf-Cell Measurements:\u003c\/strong\u003e -999 mV to +999 mV, ±5 mV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 50°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Case:\u003c\/strong\u003e IP65 rated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBS 1881-204:1988 – Recommendations for using electromagnetic covermeters.\u003c\/li\u003e\n\u003cli\u003eBS 1881-201 – Guide to Non-Destructive Methods for Hardened Concrete.\u003c\/li\u003e\n\u003cli\u003eASTM C876 – Corrosion Potentials of Uncoated Reinforcing Steel in Concrete.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Germann Instruments","offers":[{"title":"Default Title","offer_id":43509850898614,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-CoverMaster-elcometer-331-rebar-cover-meter-germann.jpg?v=1727769255"},{"product_id":"ere-probe-for-monitoring-reinforcement-in-concrete-structures","title":"ERE-Probe for monitoring reinforcement in concrete structures","description":"\u003cp\u003eThe ERE-Probe is an embeddable, half-cell reference electrode designed for accurate, long-term monitoring of corrosion activity in steel reinforcement embedded in concrete. Utilising a stable manganese dioxide composition, the ERE-Probe effectively measures the half-cell potential of steel reinforcement without inducing corrosion or altering the natural potential.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Options for New and Existing Structures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNew Structures\u003c\/strong\u003e: The ERE-Probe can be easily strapped to reinforcement with plastic ties before concrete placement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExisting Structures\u003c\/strong\u003e: A hole is drilled to the desired depth, and the ERE-Probe is embedded in a suitable cementitious mortar.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring corrosion-prone areas, such as construction joints, splash zones in marine structures, bridge decks, and column bases exposed to chlorides.\u003c\/li\u003e\n\u003cli\u003eTracking the effectiveness of cathodic protection systems.\u003c\/li\u003e\n\u003cli\u003eObserving the advancement of depassivation fronts caused by chloride penetration or carbonation, particularly when used with the CorroWatch system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: Diameter ≈ 18 mm; Length ≈ 85 mm (without protective cap)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotential\u003c\/strong\u003e: +205 ± 20 mV in saturated Ca(OH)₂ at 23°C vs Ag\/AgCl electrode*\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Resistance\u003c\/strong\u003e: \u0026lt; 5,000 Ohm in saturated Ca(OH)₂ at 23°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStability\u003c\/strong\u003e: Variation ±5 mV from initial value in identical conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +40°C (Readings recover after frost\/thaw cycles)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService Life\u003c\/strong\u003e: Exceeds 30 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ERE-Probe provides reliable and precise corrosion monitoring for concrete structures, ensuring the longevity and durability of steel reinforcement across a range of challenging environments.\u003c\/p\u003e","brand":"Germann Instruments","offers":[{"title":"Default Title","offer_id":43608664244406,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-ERE-probe-germann.webp?v=1731471804"},{"product_id":"corrowatch-4-probe-for-monitoring-system-for-reinforcement-corrosion","title":"CorroWatch 4-probe for monitoring system for reinforcement corrosion","description":"\u003cdiv class=\"flex max-w-full flex-col flex-grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"a36a54cc-7cb0-4870-88d5-b3a427795d28\" dir=\"auto\" class=\"min-h-8 text-message flex w-full flex-col items-end gap-2 whitespace-normal break-words [.text-message+\u0026amp;]:mt-5\" data-message-model-slug=\"gpt-4o\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[3px]\"\u003e\n\u003cdiv class=\"markdown prose w-full break-words dark:prose-invert light\"\u003e\n\u003cp\u003e\u003cstrong\u003eCorroWatch: Advanced 4-Probe System for Early Detection of Reinforcement Corrosion\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CorroWatch is a 4-probe monitoring device designed to provide early warnings of corrosion activity in concrete-reinforced structures. This multi-probe system features four black steel bars serving as anodes and a noble metal cathode, enabling detection of corrosion at various concrete cover depths. The anodes are attached to rebar with plastic strips and can be positioned at adjustable elevations to match the concrete cover thickness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow CorroWatch Works\u003c\/strong\u003e\u003cbr\u003eWhen concrete is poured, the CorroWatch monitors corrosion based on cover distance. By measuring current flow between each anode and the cathode using a Zero Ohm Ammeter or data logger, the CorroWatch detects significant current increases, indicating the onset of corrosion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Corrosion Monitoring with ERE-Probe Integration\u003c\/strong\u003e\u003cbr\u003eThe CorroWatch can work alongside the ERE-Probe to monitor electrical potentials in the anodes, providing a comprehensive view of corrosion activity across the structure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCorrosion monitoring in high-risk areas like construction joints, marine splash zones, bridge decks, and column bases.\u003c\/li\u003e\n\u003cli\u003eTracking the advance of the depassivation front from chloride ingress or carbonation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnodes\u003c\/strong\u003e: 4 black steel bars, each 60 mm in length and 12 mm in diameter\n\u003cul\u003e\n\u003cli\u003eDefault Heights: 33, 38, 43, and 48 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCathode Chamber\u003c\/strong\u003e: 85 mm diameter, 20 mm thickness\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 500 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CorroWatch provides reliable, early-stage corrosion detection for reinforced concrete, ensuring timely maintenance and extended structural durability in challenging environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Germann Instruments","offers":[{"title":"Default Title","offer_id":43608672731318,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-corrowatch-reinforcement-corrosion-germann.png?v=1731472253"},{"product_id":"mini-r-meter","title":"Mini R-Meter™","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eA rugged hand held field instrument for finding the location, depth and size of reinforcement rebar, post tension cable, copper and conduit in place.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch4\u003ePurchasing Notes\u003c\/h4\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eUsed in conjunction with the \u003cstrong\u003eC-CM-4000\u003c\/strong\u003e \u003cstrong\u003e\u003ca href=\"https:\/\/hyleccontrols.com.au\/products\/cor-map-basic-half-cell-system\" title=\"Cormap\"\u003eCormap® System\u003c\/a\u003e\u003ca href=\"https:\/\/www.ndtjames.com\/Cor_Map_System_p\/c-cm-i.htm\" title=\"Cormap\"\u003e\u003c\/a\u003e\u003c\/strong\u003e for economical corrosion analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch4\u003eApplications\u003c\/h4\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eRebar Locating Detection and Orientation\u003c\/li\u003e\n\u003cli\u003eMeasurement of Concrete Cover\u003c\/li\u003e\n\u003cli\u003eConcrete Drilling and Sawing\u003c\/li\u003e\n\u003cli\u003eRepair and Rehabilitation\u003c\/li\u003e\n\u003cli\u003eLocation of Prestressed Cables\u003c\/li\u003e\n\u003cli\u003eContractors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch4\u003eFeatures \u0026amp; Benefits\u003c\/h4\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eEddy current design for greater accuracy.\u003c\/li\u003e\n\u003cli\u003eSingle sensor for all depth ranges.\u003c\/li\u003e\n\u003cli\u003eDaylight visible display\u003c\/li\u003e\n\u003cli\u003eLocates up to 8\" (200 mm)\u003c\/li\u003e\n\u003cli\u003eEconomical\u003c\/li\u003e\n\u003cli\u003eStore Data for Later Upload via USB\u003cbr class=\"ProseMirror-trailingBreak\"\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Information\u003c\/h4\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe Mini R-Meter™ is a rugged digital hand-held field instrument for finding the location and depth of reinforcement bars in place.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe Mini R-Meter ™ is light weight and inexpensive, and an easy to use unit to locate rebar. Rebar detection of up to 8\" (200 mm) can be accomplished when locating large diameter rebar. An easy to read display and a 4 hr battery life are just a few advantages that make the Mini R-Meter™ one of the most advanced hand held units in the field today. The sensor design allows the end user to quickly and accurately locate and determine concrete cover in corners or hard to reach areas. The system allows the user to select between Imperial and Metric units, and the data can be saved in the instrument for posterior uploading to a computer. The data is saved in the system with the date and time of the record to help iden tify prior test taken. The Mini R-Meter™ rebar locator is also capable of locating no n-ferrous metals.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe eddy current sensor was specifically designed to react with the presence of currents on the outer surface of metal objects. It is uninfluenced by small metal particles in the concrete, whether the concrete is fresh or hardened, wet, or dry. The eddy current sensor also allows the unit to locate both ferrous as well as non-ferrous metals in concrete; thereby finding not only st eel reinforcing bars accurately, but also tendons, copper tubing, conduit, and more.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe latest in microprocessor technology not only conditions the signal from the sensor for more accurate and dependable results , but also provides the user with the information they need.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eBuilt in memory can store over 150 individual data points for later processing.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cbr\u003eDetection and Orientation of Rebar\u003c\/strong\u003e\u003cbr\u003eThe exact position and orientation of rebar can be measured quickly and accurately. Rebar-free areas can be identified for coring, grinding, resurfacing, or insertion of new machinery mountings.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe instrument can be used to inspect new structures for compliance with specifications as well as old structures under modification.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eMeasurement of Concrete Cover\u003c\/strong\u003e\u003cbr\u003eThe exact position and orientation of rebar can be measured quickly and accurately. Knowing the size of the rebar, concrete cover can be detected and the distance between the concrete and the surface it will appear in the easy to read display.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eLocation of Metals\u003c\/strong\u003e\u003cbr\u003eLocate any metals, as pipe, flues, wire, and sheets embedded in concrete, masonry, or wood. Identification is possible to a depth of 8 inches.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003eLocation of Pre-Stressed Cables\u003c\/strong\u003e\u003cbr\u003eLocates the position of cables and lost tendon splices in pre- or post-tension concrete products.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e23 deg F to 113 F (- 5 deg C to 45 C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar Size Calibration:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3\/8\" to 1-3\/8\" (10 mm to 28 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Detection Range:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8\" (with #11 Bar); 200 mm (with #36 mm Bar)\u003cbr\u003e\u003cbr class=\"ProseMirror-trailingBreak\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4 AA Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4 hours continuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCompatible with Windows 11 \/ USB Required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Weight:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLess than 3.5 pounds (1.60 Kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch4\u003eStandards\u003c\/h4\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/knowledge.bsigroup.com\/products\/testing-concrete-recommendations-on-the-use-of-electromagnetic-covermeters\/standard\"\u003eBS 1881-204:1988\u003cbr\u003eTesting concrete. Recommendations on the use of electromagnetic covermeters\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"NDT James Instruments","offers":[{"title":"Default Title","offer_id":45293920485558,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-mini-r-meter-ndt-james3.jpg?v=1785199139"},{"product_id":"cor-map-basic-half-cell-system","title":"Cor-Map® System Basic Half-Cell System for Detecting Areas of Probable Rebar Corrosion","description":"\u003ch2\u003e\u003cspan\u003eBasic Half-Cell System for Detecting Areas of Probable Rebar Corrosion\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eJames Cor-Map® System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a simple, reliable, and cost-effective half-cell potential testing system designed to identify areas of probable reinforcing steel (rebar) corrosion in concrete structures. Compliant with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASTM C876\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the Cor-Map® enables engineers, consultants, and asset owners to quickly assess corrosion activity and prioritise maintenance before significant structural damage occurs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003ePurchasing Notes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cspan\u003eFor comprehensive corrosion analysis, use in conjunction with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eJames R-C-400 Rebarscope®\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eConsumable required: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eC-CM-4210 Copper Sulphate Solution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Cor-Map® System is ideal for evaluating corrosion activity in reinforced concrete structures, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eBridge decks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eParking structures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConcrete piers and marine structures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilding substructures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTunnel linings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFoundations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCivil infrastructure inspections\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eFeatures \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cspan\u003eComplies with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASTM C876\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e half-cell potential testing\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSimple and economical corrosion assessment method\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-impedance digital voltmeter for accurate field measurements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDurable construction for demanding site conditions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDetachable electrode extension pieces for difficult-to-access locations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReference electrode suitable for horizontal, vertical and overhead testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFast identification of probable corrosion areas\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePortable and easy to operate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe James Cor-Map® System measures the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehalf-cell potential\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between embedded reinforcing steel and a copper\/copper sulphate reference electrode placed on the concrete surface. These measurements indicate the probability of active corrosion occurring within the reinforcing steel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBy taking measurements at regular intervals across a concrete surface, users can quickly create a grid of half-cell potentials. The resulting data can then be plotted to produce contour maps that highlight areas with an increased likelihood of corrosion activity, allowing targeted inspection, repair and rehabilitation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Cor-Map® System offers a practical, non-destructive solution for evaluating the condition of reinforced concrete infrastructure and planning preventative maintenance programs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eHow Half-Cell Potential Testing Works\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSteel reinforcement corrodes when moisture and oxygen penetrate the concrete and initiate an electrochemical reaction. The Cor-Map® System measures the electrical potential difference between the reinforcing steel and a stable copper\/copper sulphate reference electrode.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe measured voltage does not indicate the amount of corrosion present, but instead provides the probability that active corrosion is occurring near the measurement location.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTesting is performed over a predetermined grid, allowing engineers to generate corrosion potential maps that identify areas requiring further investigation or repair.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eInterpreting ASTM C876 Results\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUsing a Copper\/Copper Sulphate (Cu\/CuSO₄) reference electrode:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eHalf-Cell Potential\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eProbability of Active Corrosion\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGreater than 350 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 95% probability\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e200–350 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 50% probability\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 200 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 5% probability\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eTypical Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Cor-Map® System is particularly well suited for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eBridge deck inspections\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eParking garages\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConcrete wharves and docks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMarine structures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilding foundations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTunnel linings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAsset condition assessments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConcrete rehabilitation projects\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eSystem Components\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eC-CM-4500\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-impedance digital voltmeter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eC-CM-4410\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eElectrode extension pieces (18 in \/ 41 cm each)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eC-CM-4400\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCopper\/copper sulphate reference electrode with reservoir\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eC-CM-4210\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCopper sulphate container (250 ml)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eC-CM-4220\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWetting agent reservoir (125 ml)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eC-CM-4420\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDispensing sponge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eC-CM-4300\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCable reel with 250 ft (80 m) cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eC-CM-4000\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eComplete Cor-Map® System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eASTM C876 – Standard Test Method for Corrosion Potentials of Uncoated Reinforcing Steel in Concrete\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e","brand":"NDT James Instruments","offers":[{"title":"Default Title","offer_id":45294150549686,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3394\/5270\/files\/hylec-controls-cor-map-I-basic-ndt-james.jpg?v=1785199848"}],"url":"https:\/\/hyleccontrols.com.au\/collections\/rebar.oembed?page=2","provider":"Hylec Controls","version":"1.0","type":"link"}